Pure Effect Request a Quote
Treatment Systems

Groundwater Remediation Systems

An installed Pure Effect groundwater treatment train with a black poly tank and two white carbon vessels on an outdoor secondary-containment berm
Groundwater treatment train · secondary containment

Pump-and-treat systems that remove contaminants from impacted groundwater.

When groundwater at a site is contaminated, regulators require it to be treated before discharge. We build pump-and-treat remediation systems that remove dissolved contaminants, VOCs, metals, and regulated constituents such as uranium, arsenic, and boron, using pre-treatment, filtration, and granular activated carbon in vessels run in series. In California the MCL for uranium is 20 pCi/L and for arsenic 0.01 mg/L; we design the system to the site's chemistry and its discharge limits. Lease it, buy it, or have us operate it onsite.

treatment-systemsgroundwaterremediationvocuraniumarsenicboronactivated carbonrentbuy
Request a Quote Call 866.421.7873